
| Flow rate | up to 79 l/min (4.75 m3/h) | |||
| Head up | up to 30 m | |||
| Medium temperature | 2~60℃ | |||
| Operating ambient temperature | 0~55℃ | |||
| Max.suction | up to 5m | |||
| Working Noise | ≤45dB (3m³/h) | |||
| Insulation Grade | H | |||
| Ingress production | IP44 | |||

| Flow rate | up to 100 L/min ( 6 m3/h) |
| Head up | Up to 55 m |
| Max. suction head | up to 8 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for A1-250 4 bar for A1-370(S), 550(S) 5 bar for A1-750(S) 6 bar for A1-1100(S) |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | HT 200 |

| Flow rate | up to 100 L/min (6 m3/h) |
| Head up | Up to 55 m |
| Max. suction head | up to 8 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for A1-200ZJ, 300ZJ 4 bar for A1-400ZJ, 600ZJ 5 bar for A1-800ZJ 6 bar for A1-1100ZJ |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | ZL 102 |

| Flow rate | up to 110 L/min (6.5m3/h) |
| Head up | Up to 55 m |
| Max. suction head | up to 9 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for JET-370-Y 4 bar for JET-750/550-Y 5 bar for JET-920/1100-Y 6 bar for JET-1500-Y |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | PPO/ Brass |
| Shaft | AISI 304 +Steel 45# |
| Motor bracket | ZL 102 |

| Flow rate | up to 633 l/min (38 m3/h) | |||
| Head up | up to 24 m | |||
| Medium temperature | 4~50℃ | |||
| Max.suction | up to 3m | |||
| Working Noise | ≤45dB | |||
| Insulation Grade | H | |||
| Ingress production | IP44 | |||

| Flow rate | up to 55 l/min (3.3 m3/h) | |||
| Head up | up to 50 m | |||
| Medium temperature | 2~40℃ | |||
| Operating ambient temperature | 0~55℃ | |||
| Max.suction | up to 5m | |||
| Working Noise | ≤45dB (3m³/h) | |||
| Insulation Grade | H | |||
| Ingress production | IPX4 | |||

| Flow rate | up to 80 l/min (4.8 m3/h) | |||
| Head up | up to 50 m | |||
| Medium temperature | 2~40℃ | |||
| Max.suction | up to 5m | |||
| Working Noise | ≤45dB | |||
| Insulation Grade | H | |||
| Ingress production | IP44 | |||

| Flow rate | up to 60 l/min (3.5m3/h) |
| Head up | Up to 65 m |
| Max. suction head | up to 8 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for DKm60 6 bar for DKm70 7 bar for DKm80 |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 | |||
| Impeller | Brass | |||
| Shaft | Stainless steel AISI 304 | |||
| Motor bracket | ZL 102 | |||

| Flow rate | up to 50 L/min (3 m3/h) |
| Head up | Up to 42 m |
| Max. suction head | up to 8 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for DGP116, 126 4 bar for DGP130, 226 5 bar for DGP550 |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | ZL 102 |

| Flow rate | up to 80 L/min (4.8 m3/h) |
| Head up | Up to 55 m |
| Max. suction head | up to 8 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for DGP130A 4 bar for DGP226A, 550A 5 bar for DGP750A 6 bar for DGP1100A |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | ZL 102 |

| Flow rate | up to 100 L/min (6 m3/h) |
| Head up | Up to 55 m |
| Max. suction head | up to 8 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for A1-200ZW, 300ZW 4 bar for A1-400ZW, 600ZW 5 bar for A1-800ZW 6 bar for A1-1100ZW |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | ZL 102 |

| Flow rate | up to 390 L/min (24m3/h) |
| Head up | Up to 20 m |
| Max. suction head | up to 9 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 2 bar for 1DK15,1DK20, 1.5DK18, 1.5DK20, 2DK20 |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | Cast iron |
| Impeller | PPO |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | PC |

| Flow rate | up to 167 L/min (10m3/h) |
| Head up | Up to 50 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for DCm370, 550, 750 5 bar for DCm1100, 1500 6 bar for DCm2200 |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass/AISI304 |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | ZL 102 |

| Flow rate | up to 450 L/min (27m3/h) |
| Head up | Up to 25 m |
| Max. suction head | up to 9 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 2 bar for DSm60, DSm70 3 bar for DSm80 |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass/AISI304 |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | ZL 102 |

| Flow rate | up to 1180 L/min (70m3/h) |
| Head up | Up to 21 m |
| Max. suction head | up to 9 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 1 bar for DHm6C,5B 2 bar for DHm7BR, 7B, 6A,6AR,6B, 5AM,5BM |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | ZL 102 |

| Flow rate | up to 83 L/min (5 m3/h) |
| Head up | Up to 50 m |
| Max. suction head | up to 9 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 2 bar for DJSm-102/2 3 bar for DJSm-102/3 4 bar for DJSm-102/4 5 bar for DJSm-102/5 |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | PPO |
| Shaft | Stainless steel AISI 304 |
| Motor bracket | ZL 102 |

| Flow rate | up to 106 L/min (6.6 m3/h) |
| Head up | Up to 55 m |
| Max. suction head | up to 9 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 4 bar for A3-400ZWS, 600ZWS 5 bar for A3-800ZWS, 1100ZWS 6 bar for A3-1500ZWS |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | AISI 304 |
| Impeller | AISI 304 |
| Shaft | AISI 304 + Steel 45# |
| Motor bracket | ZL 102 |

| Flow rate | up to 85 L/min (5.1 m3/h) |
| Head up | Up to 60 m |
| Max. suction head | up to 9 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 3 bar for JET-370AH 4 bar for JET-550AH 5 bar for JET-750AH, 1100AH 6 bar for JET-920AH, 1500AH |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | PPO/ Brass |
| Shaft | AISI 304 +Steel 45# |
| Motor bracket | ZL 102 |

| Flow rate | up to 108 L/min (6.5 m3/h) |
| Head up | Up to 60 m |
| Max. suction head | up to 9 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 6 bar for JA150, 200 |
| Motor | 2-pole copper winding |
| Insulation Class | class F |
| Protection Class | IP X4 |
| Pump housing | HT 200 |
| Impeller | Brass |
| Shaft | AISI 304 + Steel 45# |
| Motor bracket | ZL 102 |






